ADP15-POTENTIOMETER Potentiometer Input Digital Indicator and Controller |
|
|
|
|
|
- Features
- Specification
- Dimensions
- Downloads
- Suggested Instrumentation
- Options
- Applications
- Microprocessor based design
- Full calibration & programming via keypad & communications import
- 4½ digit scaling
- Isolated inputs & outputs
- 3 year guarantee
- PID Control
- Any potentiometer
- Angular measurement
- Position measurement
The ADP15-POTENTIOMETER range of products is very versatile, accepting a wide range of different signal input types and ranges.
The ADP15-POTENTIOMETER flexibility makes it the first choice for many control system designers. Supporting products like PC software, printers, and sensors, means most customers can deal with a single supplier.
Outputs include:-
Analogue voltage and current, Industry standard digital communications, Relays, Printer Drive
Options and Accessories include:
Panel mounting via DIN rail mounting
IF25 Interface module connects up to 25 ADP15's to 1 RS232 port
Power supplies for 110/230 V AC or 9-32V DC
Communications for Printer, PLC or PC
The ADP15-POTENTIOMETER can be supplied as part of a system, and will interface directly with LCM Systems potentiometric sensors, including the PD13. Please contact our technical department to discuss your application.
|
Input Type
|
Input Ranges
|
Order code
|
| Potentiometer |
Any value in the range 100R to 10K |
RL |
Outputs
|
Details
|
Order code
|
| 0 to 1V |
|
V1 |
| 0 to 5V |
|
V2 |
| 1 to 5V |
|
V3 |
| 0 to 10V c |
|
V4 |
| -10 to +10V |
|
V5 |
| 0-1Ma |
|
A1 |
| 0-20Ma |
|
A2 |
| 4-20mA |
|
A3 |
| 10-50mA |
|
A4 |
| 0-5mA |
|
A5 |
| 0-10mA |
|
A6 |
| Pulse Frequency |
|
F1 |
Other Information
|
| Accuracy |
Typical ± 0.08% of output, ± 0.08%FSD |
| Resolution |
As display resolution, max 15 bits |
| Calibration |
By 15-turn pre sets for gain and offset |
| Inversion |
By keypad value |
| Isolation |
±130V RMS or DC max to analogue input or to any other port |
| Ranging |
Fully keypad scalable over desired display range |
| PID |
Power level, when selected = 12 bit resolution output |
Communications Port
|
Details
|
Order code
|
| RS485/232 |
RS485 - For up to 32 instruments on 1 bus, 4 wire
RS232 printer or direct connection to 1 device, 3 wire |
COM 1 |
| 20mA current loop |
For up to 25 instruments per interface, 4 wire |
S1 |
Other Information
|
| Baud rates |
300, 600, 1200, 2400, 4800, 9600 (19200 MANTRABUS only) |
| Electrical isolation |
±130V RMS or DC max to analogue input or any other port |
| Formats |
MODBUS RTU, MANTRABUS and printer output formats |
Alarm/Control
|
Outputs
|
Details Order code
|
| SPCO |
1 relay on SP1 |
R1 |
| DPCO |
1 relay on SP1 |
R2 |
| SPCO |
2 relays on SP1& 2 |
R3 |
| SPCO |
1 relay on SP2 |
R4 |
| DPCO |
1 relay on SP2 |
R5 |
Other Information
|
| Relays |
230V at 5A AC resistive |
| Isolation |
±130V RMS |
Keypad Programmable
values and options |
Hysteresis, Latching, Output Inversion, Delay Times, PID
Time Proportioning. |
| 16 relay option can be supplied on external DIN rail modules (10A SPCO). Available for DC, AC, Temperature, Strain Gauge & Potentiometer inputs, ask for ADP15-SP16 |
Power Supplies
|
Details
|
Order code
|
| 240 |
220V-230V AC 50-60Hz 10W |
240 |
| 110 |
110V-120V AC 50-60Hz 10W |
110 |
| 12 & 24V |
9-32V DC 10W isolated |
12/24 |
Mounting Type
|
Order code
|
| Front Panel |
P |
| Din Rail Adaptor |
D |
Communication Port CP Operation
|
| All ADP15 display data can be accessed via the communications port along with relay, PID power and EEPROM status. |
| All ADP15 user configurable data can be changed including EEPROM enable/disable and relay reset (ADP15 address code cannot be changed). |
Other Options & Accessories
|
| One pass calibration |
| 20mA PC Communications Interface (IF25) |
| VisualLink PC SCADA Software |
| Analogue Totaliser (Integrator) |
Base ADP15
|
| Input Filter |
Programmable to average up to 64 display updates. |
| Displays |
7 segment LED 4.5 digit 10mm.3 x 3mm LED's 2 for relay status, 1 for program and hold indication. |
| Update Rate |
Up to 10 updates per seconds |
Controls
|
| 4 membrane panel keys |
Scroll key to view/update parameter. |
| |
Digit select key. |
| |
Digit increment key. |
| |
Reset key. |
| |
Keypad disable by internal links behind front panel. |
| |
Hold function by digit select key when in input mode. |
Data Retention/Protection
|
| Retention |
10 years for set up values, minimum of 100,000 write cycle |
| |
Protection of data and function(s) Watchdog timer giving repeat auto resets |
| |
Impending power detection and hold off. |
| |
Keypad security, and time out. |
CE & Environmental
|
| Storage temperature |
-20 to +70ºC |
| Operating temperature |
-10 to 50°C |
| Relative humidity |
95% maximum non condensing |
| Safety/Low Voltage Directive |
73/23/EEC amended by 93/68/EEC
BS EN 61010-1 |
| EMC Directive |
89/336/EEC
Basic Standard BS EN 61326 |
| EMC Emissions |
BS EN 55011 |
| EMC Immunity |
BS EN 61000-42:1995
BS EN 61000-4-3:2002
BS EN 61000-4-4:2004
BS EN 61000-4-11:2004 |
Physical
|
| Case Dimensions |
DIN 72 x 72 x 163mm (excluding mounting terminal) |
| Case Material |
Grey Noryl, flame retardant |
| Weight |
750 grams |
| Terminals |
2.5mm, saddle field terminals |
| Accessibility |
All electronics removable through front panel leaving field wiring and case in situ. |
|
Please contact LCM Systems Technical Department for further Instrumentation requirement. For suitable Sensors to use with The ADP15-POTENTIOMETER, please refer to the product links below:-
PD13 Linear Displacement Transducer
|
| There are currently no options available to view from this page. To view the various input and output options available for the ADP15-POTENTIOMETER, please view the ADP15-POTENTIOMETER product datasheet by clicking here. |
- Feedback control of stroke based control systems, requiring PID control
- Distance measurement
- Angular rotation measurement
- Leveling systems
|
|
|
|
|
|