LCM Systems Logo
     


                                              
 

Solutions in Load Cell Technology
   
Home Page Icon Home | Site Map Icon Site Map
Unit 15, Newport Business Park
Barry Way, Newport
Isle of Wight, PO30 5GY
United Kingdom
TEL: +44(0)1983 249264
FAX: +44(0)1983 249266

 

ADP15-POTENTIOMETER Potentiometer Input Digital Indicator and Controller

ADP15-POTENTIOMETER Potentiometer Input Digital Indicator/Controller 

  • Features
  • Specification
  • Dimensions
  • Downloads
  • Suggested Instrumentation
  • Options
  • Applications
  • Microprocessor based design
  • Full calibration & programming via keypad & communications import
  • 4½ digit scaling
  • Isolated inputs & outputs
  • 3 year guarantee
  • PID Control
  • Any potentiometer
  • Angular measurement
  • Position measurement

The ADP15-POTENTIOMETER range of products is very versatile, accepting a wide range of different signal input types and ranges.

The ADP15-POTENTIOMETER flexibility makes it the first choice for many control system designers. Supporting products like PC software, printers, and sensors, means most customers can deal with a single supplier.

Outputs include:-

Analogue voltage and current, Industry standard digital communications, Relays, Printer Drive

Options and Accessories include:

Panel mounting via DIN rail mounting
IF25 Interface module connects up to 25 ADP15's to 1 RS232 port
Power supplies for 110/230 V AC or 9-32V DC
Communications for Printer, PLC or PC

The ADP15-POTENTIOMETER can be supplied as part of a system, and will interface directly with LCM Systems potentiometric sensors, including the PD13. Please contact our technical department to discuss your application.

Input Type

Input Ranges

Order code

Potentiometer Any value in the range 100R to 10K RL

Outputs

Details

Order code

0 to 1V   V1
0 to 5V   V2
1 to 5V   V3
0 to 10V c   V4
-10 to +10V   V5
0-1Ma   A1
0-20Ma   A2
4-20mA   A3
10-50mA   A4
0-5mA   A5
0-10mA   A6
Pulse Frequency   F1

Other Information

Accuracy Typical ± 0.08% of output, ± 0.08%FSD
Resolution As display resolution, max 15 bits
Calibration By 15-turn pre sets for gain and offset
Inversion By keypad value
Isolation ±130V RMS or DC max to analogue input or to any other port
Ranging Fully keypad scalable over desired display range
PID Power level, when selected = 12 bit resolution output

Communications Port

Details

Order code

RS485/232 RS485 - For up to 32 instruments on 1 bus, 4 wire
RS232 ­ printer or direct connection to 1 device, 3 wire
COM 1
20mA current loop For up to 25 instruments per interface, 4 wire S1

Other Information

Baud rates 300, 600, 1200, 2400, 4800, 9600 (19200 MANTRABUS only)
Electrical isolation ±130V RMS or DC max to analogue input or any other port
Formats MODBUS RTU, MANTRABUS and printer output formats

Alarm/Control

Outputs

Details Order code

SPCO 1 relay on SP1 R1
DPCO 1 relay on SP1 R2
SPCO 2 relays on SP1& 2 R3
SPCO 1 relay on SP2 R4
DPCO 1 relay on SP2 R5

Other Information

Relays 230V at 5A AC resistive
Isolation ±130V RMS
Keypad Programmable
values and options
Hysteresis, Latching, Output Inversion, Delay Times, PID
Time Proportioning.
16 relay option can be supplied on external DIN rail modules (10A SPCO). Available for DC, AC, Temperature, Strain Gauge & Potentiometer inputs, ask for ADP15-SP16

Power Supplies

Details

Order code

240 220V-230V AC 50-60Hz 10W 240
110 110V-120V AC 50-60Hz 10W 110
12 & 24V 9-32V DC 10W isolated 12/24

Mounting Type

Order code

Front Panel P
Din Rail Adaptor D

Communication Port CP Operation

All ADP15 display data can be accessed via the communications port along with relay, PID power and EEPROM status.
All ADP15 user configurable data can be changed including EEPROM enable/disable and relay reset (ADP15 address code cannot be changed).

Other Options & Accessories

One pass calibration
20mA PC Communications Interface (IF25)
VisualLink PC SCADA Software
Analogue Totaliser (Integrator)

Base ADP15

Input Filter Programmable to average up to 64 display updates.
Displays 7 segment LED 4.5 digit 10mm.3 x 3mm LED's 2 for relay status, 1 for program and hold indication.
Update Rate Up to 10 updates per seconds

Controls

4 membrane panel keys Scroll key to view/update parameter.
  Digit select key.
  Digit increment key.
  Reset key.
  Keypad disable by internal links behind front panel.
  Hold function by digit select key when in input mode.

Data Retention/Protection

Retention 10 years for set up values, minimum of 100,000 write cycle
  Protection of data and function(s) Watchdog timer giving repeat auto resets
  Impending power detection and hold off.
  Keypad security, and time out.

CE & Environmental

Storage temperature -20 to +70ºC
Operating temperature -10 to 50°C
Relative humidity 95% maximum non condensing
Safety/Low Voltage Directive 73/23/EEC amended by 93/68/EEC
BS EN 61010-1
EMC Directive 89/336/EEC
Basic Standard BS EN 61326
EMC Emissions BS EN 55011
EMC Immunity BS EN 61000-42:1995
BS EN 61000-4-3:2002
BS EN 61000-4-4:2004
BS EN 61000-4-11:2004

Physical

Case Dimensions DIN 72 x 72 x 163mm (excluding mounting terminal)
Case Material Grey Noryl, flame retardant
Weight 750 grams
Terminals 2.5mm, saddle field terminals
Accessibility All electronics removable through front panel leaving field wiring and case in situ.
adp15 drawing

Please contact LCM Systems Technical Department for further Instrumentation requirement. For suitable Sensors to use with The ADP15-POTENTIOMETER, please refer to the product links below:-

PD13 Linear Displacement Transducer

There are currently no options available to view from this page. To view the various input and output options available for the ADP15-POTENTIOMETER, please view the ADP15-POTENTIOMETER product datasheet by clicking here.
  • Feedback control of stroke based control systems, requiring PID control
  • Distance measurement
  • Angular rotation measurement
  • Leveling systems

Powered By Intergage | Content Management System