ADP15 AC-DC Voltage and Current Input Digital Indicator and Controller |
|
|
|

- Features
- Specification
- Dimensions
- Downloads
- Suggested Instrumentation
- Options
- Applications
- Microprocessor based design
- Full calibration & programming via keypad & communications import
- Isolated inputs & outputs range AC & DC powering
- 3 year guarantee
- PID Control
- Isolated Analogue Outputs
- Fail safe alarm/relay outputs
- 4½ digit high resolution
- AC Voltage 0 to 200V
- AC Current 0 to 1Amp
- DC Voltages 20mV to 200V
- DC Current 2mV to 200mA
- Peak hold
The ADP15 range of products is very versatile, accepting a wide range of different signal input types and ranges.
The ADP15 flexibility makes it the first choice for many control system designers. Supporting products like PC software, printers, and sensors, means most customers can deal with a single supplier.
Outputs include:- Analogue voltage and current, Industry standard digital communications, Relays, Printer Drive.
Options and Accessories include:-
Panel mounting via DIN rail mounting
IF25 Interface module (connects up to 25off ADP15's to one RS232 port)
Power supplies for 110/230VAC or 9-32VDC
Communications for Printer, PLC or PC Software Options:- Power Factor Printers DP data only and TDP for real time/date.
The ADP15 can be supplied as part of a system, including many of the wide range of LCM Systems sensors and instrumentation. Please contact our technical department to discuss your application.
|
Input Type
|
Input Ranges
|
Order code
|
| DC Voltage |
+/-20mV |
DCV1 |
| |
+/-200mV |
DCV2 |
| |
+/-2V |
DCV3 |
| |
+/-20V |
DCV4 |
| |
+/-200V |
DCV5 |
| DC Current |
+/-2mA |
DCA1 |
| |
4-20mA (3.5mA to 20.5mA) |
DCA2E |
| |
+/-20mA |
DCA3 |
| |
+/-200mA |
DCA4 |
| AC Voltage |
0-200mV |
ACV1 |
| |
0-2V |
ACV2 |
| |
0-20V |
ACV3 |
| |
0-200V |
ACV4 |
| AC Current |
0-1A |
ACA |
Outputs
|
Details
|
Order code
|
| 0 to 1V |
|
V1 |
| 0 to 5V |
|
V2 |
| 1 to 5V |
|
V3 |
| 0 to 10V |
|
V4 |
| ±10V |
|
V5 |
| 0-1mA |
|
A1 |
| 0-20mA |
|
A2 |
| 4-20mA |
|
A3 |
| 10-50mA |
|
A4 |
| 0-5mA |
|
A5 |
| 0-10mA |
|
A6 |
Other Information
|
| Accuracy |
Typical ±0.08% of output, ± 0.08%FSD |
| Resolution |
As display resolution, max 15 bits |
| Calibration |
By 15-turn pre sets for gain and offset |
| Inversion |
By keypad value |
| Isolation |
±130V RMS or DC max to analogue input or to any other port |
| Ranging |
Fully keypad scalable over desired display range |
| PID |
Power level, when selected = 12 bit resolution output |
Communications Port
|
Details
|
Order code
|
| RS485/232 |
RS485 - For up to 32 instruments on 1 bus, 4 wire
RS232 printer or direct connection to 1 device, 3 wire |
COM 1 |
| 20mA current loop |
For up to 25 instruments per interface, 4 wire |
S1 |
Other Information
|
| Baud rates |
300, 600, 1200, 2400, 4800, 9600 (19200 MANTRABUS only) |
| Electrical isolation |
±130V RMS or DC max to analogue input or any other port |
| Formats |
MODBUS RTU, MANTRABUS and printer output formats |
Alarm/Control Outputs
|
Details
|
Order code
|
| SPCO |
1 relay on SP1 |
R1 |
| DPCO |
1 relay on SP1 |
R2 |
| SPCO |
2 relays on SP1& 2 |
R3 |
| SPCO |
1 relay on SP2 |
R4 |
| DPCO |
1 relay on SP2 |
R5 |
Other Information
|
| Relays |
230V at 5A AC resistive |
| Isolation |
±130V RMS |
| Keypad Programmable |
Hysteresis, Latching, Output Inversion, Delay Times, |
| PID values and options |
Time Proportioning. |
| 16 relay option can be supplied on external DIN rail modules (10A SPCO), ask for ADP15-SP16 |
Power Supplies
|
Details
|
Order code
|
| 240 |
220V-230V AC 50-60Hz 10W |
240 |
| 110 |
110V-120V AC 50-60Hz 10W |
110 |
| 12 & 24V |
9-32V DC 10W isolated |
12/24 |
Mounting Type
|
Order code
|
| Front Panel |
P |
| Din Rail Adaptor |
D |
Communication Port CP Operation
|
| All ADP15 display data can be accessed via the communications port along with relay, PID power and EEPROM status. |
| All ADP15 user configurable data can be changed including EEPROM enable/disable and relay reset (ADP15 address code cannot be changed). |
Other Options & Accessories
|
| One pass calibration |
| 20mA PC Communications Interface (IF25) |
| VisualLink PC SCADA Software |
| Analogue Totaliser (Integrator) |
Base ADP15
|
| Input Filter |
Programmable to average up to 64 display updates. |
| Displays |
7 segment LED 4.5 digit 10mm.3 x 3mm LED's 2 for relay status, 1 for program and hold indication. |
| Update Rate |
Up to 10 updates per seconds |
Controls
|
| 4 membrane panel keys |
Scroll key to view/update parameter. |
| |
Digit select key. |
| |
Digit increment key. |
| |
Reset key. |
| |
Keypad disable by internal links behind front panel. |
| |
Hold function by digit select key when in input mode. |
Data Retention/Protection
|
| Retention |
10 years for set up values, minimum of 100,000 write cycle |
| |
Protection of data and function(s) Watchdog timer giving repeat auto resets. |
| |
Impending power detection and hold off. |
| |
Keypad security and time out. |
CE & Environmental
|
| Storage temperature |
-20 to +70ºC |
| Operating temperature |
-10 to 50°C |
| Relative humidity |
95% maximum non condensing |
| Safety/Low Voltage Directive |
73/23/EEC amended by 93/68/EEC
BS EN 61010-1:2001, IEC 1010-1-1990 |
| EMC Directive |
89/336/EEC
Basic Standard BS EN 61326:1998 |
| EMC Emissions |
BS EN 55011:1998 |
| EMC Immunity |
BS EN 61000-42:1995
BS EN 61000-4-3:2002
BS EN 61000-4-4:2004
BS EN 61000-4-11:2004 |
Physical
|
| Case Dimensions |
DIN 72 x 72 x 163mm (excluding mounting terminal) |
| Case Material |
Grey Noryl, flame retardant |
| Weight |
750 grams |
| Terminals |
2.5mm, saddle field terminals |
| Accessibility |
All electronics removable through front panel leaving field wiring and case in situ. |
|
| There are currently no options available to view from this page. To view the various input and output options available for the ADP15, please view the ADP15 product datasheet by clicking here. |
- Remote display of process variables
- PID control for pressure/load controlled systems
- Crane load monitoring and protection
- Can be used with any load cell or pressure transducer from LCM Systems, with built in amplifier
|
|
|
|
|
|