- All standard ADW15 system features retained
- Programmable from the ADW keypad
- 4 and 8 relay Din Rail modules
- Individual set point, In-flight & hysterisis values
- Programmable output actions
- Selectable setpoint values
- Relay contact rating 230V @ 5A AC
- Standard Strain Gauge input 100mS sampling rate
- Industry Standard Analogue Outputs
- Output Relays, Communications, Printer Drive
The DIN rail mounted remote relay units offer an increased number of set points over that provided by a standard ADW15 strain gauge indicator/controller. This allows for multi action operations such as batch and recipe control.
The software of the ADW15-SP16 gives the user freedom to program the number of set points for their requirements. A single ADW15-SP16 will control up to 16 set points, programmed from its front panel. Set points can be individually set up with In Flight compensation and hysteresis values. Separate 'Output Latch' and 'Output Action' for up to 14 of the16 set points is available, settable from the front panel of the ADW15-SP16. A special mnemonic allows the user to specify the number of set points to be used.
A DIN rail mounted power supply unit is required where more than 4 set points are to be used. The units are driven from the ADW-SP16 via an internal, special remote driver board. All relays are pluggable and connections are made via field screw terminals. The operating procedures for these units are to be considered together with the standard ADW15 when preparing the system for operation.
Outputs include:-
Analogue voltage and current, Industry standard digital communications, Relays, Printer Drive
Options and Accessories include:-
Panel mounting via DIN rail mounting, IF25 Interface module connects up to 25 ADPs to 1 RS232 port, Power supplies for 110/230 V AC or 9-32V DC, Communications for Printer, PLC or PC.
Software Options include:-
Power Factor Printers DP data only and TDP for real time/date. Printers DP data only and TDP for real time/date.
LCM Systems can supply this as a calibrated system with any of our range of compatible sensors. Please contact our technical department, to discuss your application.
|
Input Type
|
Input Ranges
|
Order code
|
| Temperature |
Platinum Pt100 Resistance Bulb |
PT |
| |
Type K Thermocouple |
T1 |
| |
Type J Thermocouple |
T2 |
| |
Type R Thermocouple |
T3 |
| |
Type S Thermocouple |
T4 |
| |
Type T Thermocouple |
T5 |
| |
Type B Thermocouple |
T6 |
| |
Type N Thermocouple |
T7 |
| |
Type E Thermocouple |
T8 |
| DC Voltage |
+/-20mV |
DCV1 |
| |
+/-200mV |
DCV2 |
| |
+/-2V |
DCV3 |
| |
+/-20V |
DCV4 |
| |
+/-200V |
DCV5 |
| DC Current |
+/-2mA |
DCA1 |
| |
4-20mA (+ 3.5mA to 20.5mA) |
DCA2E |
| |
+/-20mA |
DCA3 |
| |
+/-200mA |
DCA4 |
| AC Voltage |
0-200mV |
ACV1 |
| |
0-2V |
ACV2 |
| |
0-20V |
ACV3 |
| |
0-200V |
ACV4 |
| AC Current |
0-1A |
ACA |
| Potentiometer |
Any value in the range 100R to 10K |
RL |
| LVDT |
AC excitation with signal selectable 20mV to 10V full range |
LVDT |
Outputs
|
Order code
|
| 0 to 1V |
V1 |
| 0 to 5V |
V2 |
| 1 to 5V |
V3 |
| 0 to 10V |
V4 |
| ±10V |
V5 |
| 0-1mA |
A1 |
| 0-20mA |
A2 |
| 4-20mA |
A3 |
| 10-50mA |
A4 |
| 0-5mA |
A5 |
| 0-10mA |
A6 |
Other Information
|
| Accuracy |
Typical ±0.08% of output, ± 0.08%FSD |
| Resolution |
As display resolution, max 15 bits |
| Calibration |
By 15-turn pre sets for gain and offset |
| Inversion |
By keypad value |
| Isolation |
±130V RMS or DC max to analogue input or to any other port |
| Ranging |
Fully keypad scalable over desired display range |
| PID |
Power level, when selected = 12 bit resolution output |
Communications Port
|
Details
|
Order code
|
| RS485/232 |
RS485 - For up to 32 instruments on 1 bus, 4 wire
RS232 printer or direct connection to 1 device, 3 wire |
COM 1 |
| 20mA current loop |
For up to 25 instruments per interface,
4 wire |
S1 |
| |
RS232 printer or direct connection to 1 device, 3 wire |
|
| 20mA current loop |
For up to 25 instruments per interface, |
S1 |
Other Information
|
| Baud rates |
300, 600, 1200, 2400, 4800, 9600 (19200 MANTRABUS only) |
| Electrical isolation |
±130V RMS or DC max to analogue input or any other port |
| Formats |
MODBUS RTU, MANTRABUS and printer output formats |
Alarm/Control Outputs
|
Details
|
Order code
|
| SPCO |
4 relay module |
REM4 |
| SPCO |
8 relay module (PSU required) |
REM8 |
| PSU |
Power supply for REM8 module |
REMPSU |
| REM cable |
REM to REM cable (req. for additional REM units) |
REMC2 |
| DPCO |
1 relay on SP2 |
R5 |
Other Information
|
|
| Relays |
230V at 5A AC resistive |
| Isolation |
±130V RMS |
| Keypad Programmable values and options |
Hysteresis, Latching, Output Inversion, Delay Times, Time Proportioning. |
PID |
| 16 relay option can be supplied on external DIN rail modules (10A SPCO), ask for ADP15-SP16 |
Power Supplies
|
Details
|
Order code
|
| 240 |
220V-230V AC 50-60Hz 10W |
240 |
| 110 |
110V-120V AC 50-60Hz 10W |
110 |
| 12 &24V |
9-32V DC 10W isolated |
12/24 |
Mounting Type
|
Order code
|
| Front Panel |
P |
| Din Rail Adaptor |
D |
Communication Port CP Operation
|
|
| All ADP15 display data can be accessed via the communications port along with relay, PID power and EEPROM status. |
| All ADP15 user configurable data can be changed including EEPROM enable/disable and relay reset (ADP15 address code cannot be changed). |
Other Options & Accessories
|
| One pass calibration |
| 20mA PC Communications Interface (IF25) |
| VisualLink PC SCADA Software |
| Analogue Totaliser (Integrator) |
Base ADP15
|
| Input Filter |
Programmable to average up to 64 display updates. |
| Displays |
7 segment LED 4.5 digit 10mm.3 x 3mm LED's 2 for relay status, 1 for program and hold indication. |
| Update Rate |
Up to 10 updates per seconds |
Controls
|
| 4 membrane panel keys |
Scroll key to view/update parameter. |
| |
Digit select key. |
| |
Digit increment key. |
| |
Reset key. |
| |
Keypad disable by internal links behind front panel. |
| |
Hold function by digit select key when in input mode. |
Data Retention/Protection
|
| Retention |
10 years for set up values, minimum of 100,000 write cycle |
| |
Protection of data and function(s) Watchdog timer giving repeat auto resets. |
| |
Impending power detection and hold off. |
| |
Keypad security and time out. |
CE & Environmental
|
| Storage temperature |
-20 to +70ºC |
| Operating temperature |
-10 to 50°C |
| Relative humidity |
95% maximum non condensing |
| Safety/Low Voltage Directive |
73/23/EEC amended by 93/68/EEC BS EN 61010-1:2001, IEC 1010-1-1990 |
| EMC Directive |
89/336/EECBasic Standard BS EN 61326:1998 |
| EMC Emissions |
BS EN 55011:1998 |
| EMC Immunity |
BS EN 61000-42:1995 BS EN 61000-4-3:2002
BS EN 61000-4-4:2004
BS EN 61000-4-11:2004 |
Physical
|
| Case Dimensions |
DIN 72 x 72 x 163mm (excluding mounting terminal) |
| Case Material |
Grey Noryl, flame retardant |
| Weight |
750 grams |
| Terminals |
2.5mm, saddle field terminals |
| Accessibility |
All electronics removable through front panel leaving field wiring and case in situ. |
|
| There are currently no options available to view from this page. To view the various input and output options available for the ADW15-SP16, please view the ADW15-SP16 product datasheet by clicking here. |
- Vessel/Silo weighing
- Simple batch control
- General force measurement
- Machinery condition monitoring
- Pump and motor torque control
- Crane overload protection
- Crane weighing
|
|
|
|
|
|