| Rated Load (kg): |
5, 10, 20, 50, 100, 200, 500 |
| Proof Load: |
150% of Rated Load |
| Ultimate Breaking Load: |
>300% of Rated Load |
| Output: |
2 mV/V at Rated Load (±10%) |
| Accuracy: |
<±0.025% of Rated Load |
| Non-Repeatability: |
<±0.020% of Rated Load |
| Excitation Voltage: |
10vdc recommended, 15vdc maximum |
| Bridge Resistance: |
350Ω |
| Insulation Resistance: |
>500MΩ @ 100vdc |
| Operating Temperature Range: |
-20 to +70°C |
| Compensated Temperature Range: |
-10 to +40°C |
| Zero Temperature Coefficient: |
<±0.002% of Rated Load/°C |
| Span Temperature Coefficient: |
<±0.001% of Rated Load/°C |
| Environmental Protection Level: |
IP68 |
| Connection Type: |
PUR screened cable 3m long, via cable gland |
| Options Available: |
Vessel mounting assembly
Shock mounting assembly |