| Rated Load (tonne) |
2, 5, 10, 25, 50, 100, 200, 300, 500, 750, 1000 |
| Proof Load |
150% of Rated Load |
| Ultimate Breaking Load |
>300% of Rated Load |
| Output |
1.5 mV/V at Rated Load (nominal) |
| Non-Linearity |
<±0.25% of Rated Load (typically) |
| Non-Repeatability |
<±0.04% of Rated Load |
| Excitation Voltage |
10vdc recommended, 15vdc maximum |
| Bridge Resistance |
700Ω (2-50tonne), 1400Ω (100-1000tonne) |
| Insulation Resistance |
>500MΩ @ 500vdc |
| Operating Temperature Range |
-20 to +70°C |
| Compensated Temperature Range |
-10 to +50°C |
| Zero Temperature Coefficient |
<±0.010% of Rated Load/°C |
| Span Temperature Coefficient |
<±0.010% of Rated Load/°C |
| Environmental Protection Level |
IP67 |
| Wiring Connections: |
| Red +ve supply |
Blue -ve supply |
| Green +ve signal |
Yellow -ve signal |
|
| Options Available |
Special ranges and sizes available
Special electrical connections
Integral signal conditioning
Submersible versions available
Domed Top/Loading Cap option
Verification Standard versions available
Mounting Base |