Parameter
|
| |
Min |
Typ |
Max |
Units |
| Power supply (SGA/A):- (110/230Vac) 50 - 60Hz |
- |
110/230 |
- |
V AC |
| Power supply DC :- |
18 |
- |
24* |
V DC |
| Power supply current DC :- (depends on loading ) |
50 |
90 |
200 |
mA |
| Bridge excitation 350R Bridge |
9.5 |
10 |
10.5 |
VDC |
| Bridge resistance |
85 |
- |
- |
Ohms |
| Bridge sensitivity (Switchable) |
0.06 |
2.5 |
29 |
mV/V |
| Gain adjustment (Pot - fine adjustment.) |
0.06 |
- |
1.0 |
mV/V |
| Offset adjustment (Pot - fine adustment.) |
-1.25 |
- |
+1.25 |
%FR |
| Offset adjustment (Switchable - coarse adjustment) |
±1.25 |
- |
±79 |
%F |
| Output load (Voltage output) |
- |
- |
2 |
mA |
| Output load (Current output) |
0 |
- |
500 |
Ohms |
| Bandwidth (No filter and > 2mV/V) -3dB point |
DC |
- |
6 |
kHz |
| Filter cut-off (Switchable ranges) -3dB point |
1 |
- |
5000 |
Hz |
| Zero temperature coefficient (@2.5mV/V) |
- |
0.002 |
0.009 |
%/ºC@2.5mV/V |
| Span temperature coefficient |
- |
0.007 |
0.01 |
%°C |
| Linearity |
- |
0.03 |
- |
%FR |
| Gain stability -1st 1000 Hours |
- |
0.2 |
- |
%FR |
| Gain stability - 2nd 1000 Hours |
- |
0.1 |
- |
%FR |
| 90 day Offset stability |
- |
3.3 |
- |
uV |
| Output load stability gain (0 - 100%) |
- |
- |
0.01 |
%FR |
| Output load stability offset (0 - 100%) |
- |
- |
0.01 |
%FR |
| Power supply rejection gain (0 - 100%) |
- |
- |
0.01 |
%FR |
| Power supply rejection offset (0 - 100%) |
- |
- |
0.01 |
%FR |
| Operating temperature range |
- 20 |
- |
50 |
°C |
| Storage temperature range |
-40 |
- |
70 |
°C |
| Humidity |
- |
- |
95 |
% |
| *N.B. 18V max at full load FR= Full Range |
| Output options set by on board switch |
±10V, ±5V, 0-10V, 0-5V, 0-20mA, 4-20Ma |
| Connections |
Field screw terminals - 2.5mm² rising clamp |
| Enclosure |
ABS case 160 x 80 x 55sealed to IP65 fitted with 3off cable glands |
| Controls |
Gain pot Offset pot
Coarse gain switches
Coarse offset switches
Filter cut-off switches
Output mode switch |
CE & Environmental
|
| Storage temperature |
-20 to +70ºC |
| Operating temperature |
-10 to 50°C |
| Relative humidity |
95% maximum non condensing |
| Safety/Low Voltage Directive |
73/23/EEC amended by 93/68/EECBS EN 61010-1:2001, IEC 1010-1-1990 |
| EMC Directive |
89/336/EECBasic Standard BS EN 61326:1998 |
| EMC Emissions |
BS EN 55011:1998 |
| EMC Immunity |
BS EN 61000-42:1995 BS EN 61000-4-3:2002
BS EN 61000-4-4:2004
BS EN 61000-4-11:200 |
| Order Codes |
SGA/A - 110/230v ac and/or 18-24v dc powered |
| |
SGA/D - 18-24v dc powered |