| Rated Load (tonnes) |
1, 2, 3¼, 4¾, 6½, 9½, 12, 15, 25, 35 |
| Proof Load |
150% of Rated Load |
| Ultimate Breaking Load |
300% of Rated Load |
| Output |
1.5 mV/V at Rated Load (nominal) |
| Non-Linearity |
< ±1.0% of Rated Load (typically) |
| Non-Repeatability |
< ±0.10% of Rated Load |
| Excitation Voltage |
10vdc recommended, 15vdc maximum |
| Bridge Resistance |
350Ω |
| Insulation Resistance |
> 500MΩ @ 500vdc |
| Operating Temperature Range |
-20 to +70°C |
| Compensated Temperature Range |
-10 to +50°C |
| Zero Temperature Coefficient |
< ±0.010% of Rated Load/°C |
| Span Temperature Coefficient |
< ±0.010% of Rated Load/°C |
| Environmental Protection Level |
IP66 (IP67 optional) |
| Connection Type |
10 metre 4-core screened PUR cable (glanded exit) |
| Wiring Connections |
| Red -ve supply |
Blue -ve supply |
| Green +ve signal |
Yellow -ve signal |
|
| Connection Type |
Special ranges available
Special electrical connections
Integral signal conditioning
Centralising Bobbin
Subsea and Offshore versions
Lloyd’s, ABS or DNV witness testing |