LCM Systems Logo
     


                                              
 

Solutions in Load Cell Technology
   
Home Page Icon Home | Site Map Icon Site Map
Unit 15, Newport Business Park
Barry Way, Newport
Isle of Wight, PO30 5GY
United Kingdom
TEL: +44(0)1983 249264
FAX: +44(0)1983 249266

 

ICA In-Cell Analogue Strain Gauge Amplifier

ICA In-Cell Analogue Strain Gauge Amplifier

 

  • Features
  • Specification
  • Dimensions
  • Downloads
  • Suggested Instrumentation
  • Options
  • Applications
  • Standardised mounting hole for faster & easier installation
  • Standardised excitation 5V DC
  • Full CE approval
  • Plated through holes for wire connections
  • Maximum height 7.6mm
  • Cost effective with attractive discounts on quantity orders
  • Robust design, reverse polarity & short circuit protected
  • Fast calibration procedure
  • Can be integrated into the majority of LCM Systems sensor products

The second generation ICA (in cell amplifier) is an extremely high performance strain gauge amplifier, converting a strain gauge input to a volt or a mA output.

Its sub-miniature design enables it to be fitted into the majority of transducers for a wide range of signal conditioning for strain gauges, load cells, pressure and torque transducers.

The amplifier is available in six versions, offering a range of current and voltage outputs. All amplifiers have a wide operating voltage range.

LCM Systems can integrate any of the ICA range of products into the majority of our sensor range. For applications where this is not possible, we can supply a small inline enclosure (ILE), which incorporates the ICA.

Specifications­ Voltage Output Versions

ICA1 - 3 Wire 0.1-10 volts

Electrical and Environmental

  Min Typ Max Units (Notes)
Power Supply 13 24 30 V DC (note 1)
Operating Current - 23 - mA (note 2)
Operating temperature range -40 - 85 °C
Storage temperature range -40 - 85 °C
Reverse polarity protection - - -30 V

Measurement

Bridge excitation 4.9 5 5.1 V
Bridge resistance 330 350 5000 Ohms
Bridge sensitivity 0.5 2.5 150 mV/V (note 3)
Output voltage range +0.1 - +10.1 V
Output load 5000 - - Ohms
Band width dc - 1000 Hz
Zero adjustment - ±2 - %FR
Span adjustment - ±8 - %FR
Linearity - 0.02 - %FR
Zero temp stability - 0.0004 0.0015 ±%FR/°C
Span temp stability - 0.002 0.0051 ±%FR/°C

ICA2 - 3 Wire 0.1-5 volts

Electrical and Environmental

  Min Typ Max Units (Notes)
Power supply 8.5 - 28 V DC (note 1)
Operating Current - 23 - mA (note 2)
Operating temperature range -40 - 85 °C
Storage temperature range -40 - 85 °C
Reverse polarity protection - - -30 V
Measurement        
Bridge excitation 4.9 5 5.1 V
Bridge resistance 330 350 5000 Ohms
Bridge sensitivity 0.5 2.5 150 mV/V (note 3)
Output voltage range +0.1 - +5.1 V
Output load 5000 - - Ohms
Band width dc - 1000 Hz
Zero adjustment - ±2 - %FR
Span adjustment - ±8 - %FR
Linearity - 0.02 - %FR
Zero temp stability - 0.0004 0.0015 ±%FR/°C
Span temp stability - 0.002 0.0051 ±%FR/°C

ICA3 - 4 Wire ±10 volts

Electrical and Environmental

  Min Typ Max Units (Notes)
Power supply ±13 - ±15 V DC (note 1)
Operating Current - 23 - mA (note 2)
Operating temperature range -40 - 85 °C
Storage temperature range -40 - 85 °C
Reverse polarity protection - - -30 V

Measurement

Bridge excitation 4.9 5 5.1 V
Bridge resistance 330 350 5000 Ohms
Bridge sensitivity 0.5 2.5 150 mV/V (note 3)
Output voltage range -10 - +10 V
Output load 5000 - - Ohms
Band width dc - 1000 Hz
Zero adjustment - ±2 - %FR
Span adjustment -   ±8 -
Linearity - 0.02 - %FR
Zero temp stability - 0.0004 0.0015 ±%FR/°C
Span temp stability - 0.002 0.0051 ±%FR/°

ICA6 - 4 Wire ±10 volts

Electrical and Environmental

  Min Typ Max Units (Notes)
Power supply 14 - 18 V DC (note 1)
Operating Current - 30 - mA (note 2)
Operating temperature range -40 - 85 °C
Storage temperature range -40 - 85 °C
Reverse polarity protection - - -30 V

Measurement

Bridge excitation 4.9 5 5.1 V
Bridge resistance 330 350 5000 Ohms
Bridge sensitivity 0.5 2.5 150 mV/V (note 3)
Output voltage range -10 - +10 V
Output load 5000 - - Ohms
Band width dc - 1000 Hz
Zero adjustment - ±2 - %FR
Span adjustment - ±8 - %FR
Linearity - 0.02 - %FR
Zero temp stability - 0.0004 0.0015 ±%FR/°C
Span temp stability - 0.002 0.0051 ±%FR/°C

Notes

Note 1 ICA6 Max Voltage can be increased to 24V with 1000R load cell.
Note 2 With 350R load cell connected.
Note 3 Factory setting is the typical value shown. For other values fit an alternative calibration resistor (see manual).

General Notes

The voltage between either of the power supply connections and the load cell shield should not exceed 50V. Any leakage will be greater than 10M Ohms.
FR = Full Range

Specifications ­ Current Output Versions

ICA4 - 3 Wire 4-20mA

Electrical and Environmental

  Min Typ Max Units (Notes)
Power supply 10 24 30 V DC
Operating Current 27 - 43 mA (note 1)
Operating temperature range -40 - 85 °C
Storage temperature range -40 - 85 °C
Reverse polarity protection - - -30 V

Measurement

Bridge excitation 4.9 5 5.1 V (note 3)
Bridge resistance 330 350 5000 Ohms(note 4)
Bridge sensitivity 0.5 2.5 150 mV/V (note 5)
Output current range 4 - 20 mA
Output load - - 250 Ohms(note 6)
Band width dc - 1000 Hz
Zero adjustment - ±2 - %FR(note 3)
Span adjustment - ±8 - %FR
Linearity - 0.02 - %FR
Zero temp stability - 0.0004 0.0015 ±%FR/°C
Span temp stability - 0.002 0.0051 ±%FR/°C

ICA5 - 2 Wire 4-20mA

Electrical and Environmental

  Min Typ Max Units (Notes)
Power supply 7.5 24 30 V DC (note 1)
Operating Current 4 - 20 mA (note 2)
Operating temperature range -40 - 85 °C
Extended operating temperature range -40 - 125 °C (note 3)
Storage temperature range -40 - 125 °C
Reverse polarity protection - - -30 V

Measurement

Bridge excitation 1.05 1.11 1.16 V (note 4)
Bridge resistance 350 1000 5000 Ohms (note 5)
Bridge sensitivity 0.5 2.5 55 mV/V (note 6)
Output voltage range 4 - 20 mA
Output load - - 800 Ohms (note 7)
Band width dc - 1000 Hz
Zero adjustment - ±2 - %FR (note 3)
Span adjustment - ±8 - %FR
Linearity - 0.02 - %FR
Zero temp stability - 0.001 0.005 ±%FR/°C
Span temp stability - 0.007 0.014 ±%FR/°C

Notes

Note 1 The ICA4 can tolerate a lower supply voltage if the output load is reduced e.g. operation is possible at 8V provided that the load does not exceed 250 Ohms in sink mode or 150 Ohms in source mode.
Note 2 With 350 Ohm load cell connected (ICA5 1000 Ohm) (recommended).
Note 3 With reduced supply voltage (see manual).
Note 4 ICA5 with 1000 Ohms load cell connected.
Note 5 ICA5 recommended bridge impedance is 1000 Ohms.
Note 6 Factory setting is the typical value shown. For other values an alternative calibration resistor (see manual).
Note 7 ICA4 only: The maximum

General Notes

The voltage between either of the power supply connections and the load cell shield should not exceed 50V. Any leakage will be greater than 10M Ohms.
FR = Full Range
Enclosure
Fit into circular holes 19.5mm diameter with 7.6mm height
Controls
Offset & gain pot +SOT resistors for mV/V sensitivity (gain)

CE & Environmental

Storage temperature refer to above specifications
Operating temperature refer to above specifications
Relative humidity 95% maximum non condensing
Safety/Low Voltage Directive 73/23/EEC amended by 93/68/EECBS EN 61010-1:2001, IEC 1010-1-1990
EMC Directive 89/336/EECBasic Standard BS EN 61326:1998
EMC Emissions BS EN 55011:1998
EMC Immunity BS EN 61000-42:1995
BS EN 61000-4-3:2002
BS EN 61000-4-4:2004
BS EN 61000-4-11:20
ica drawing

Listed below are some of the other Instruments in our range that can interfaced with any of the ICA range of products:-

ADP15 Panel Mounting Process Input Digital Indicator/Controller

ADP15-DI Dual Input Panel Mounting Digital Indicator/Controller

Alternatively, the following Load Cells are available with any of the ICA range of products internally mounted to offer an amplified output and signal conditioned Load Cell:-

CPA Stainless Steel Compression Load Cell

LMP Stainless Steel Load Monitoring Load Pin

SHK-B Bow Shackle Load Cell

SHK-D D Shackle Load Cell

TCA Stainless Steel Tension/Compression Load Cell

TLL Stainless Steel Load Monitoring Link Load Cell

There are currently no options available to view from this page. To view the various options which may be available for the ICA, please view the ICA product datasheet by clicking here.
  • Internal amplification of strain gauge based pressure transducers
  • Internal amplification of strain gauge based load cells
  • Internal amplification of strain gauge based torque transducers

Powered By Intergage | Content Management System