| Rated Load (tonne) |
1, 2, 3¼, 4¾, 6½, 9½, 12, 17
25, 40, 55, 85, 120, 200, 300, 400 |
| Proof Load |
150% of Rated Load |
| Ultimate Breaking Load |
> 300% of Rated Load |
| Output |
1.5 mV/V at Rated Load (nominal) |
| Non-Linearity |
< ±1.0% of Rated Load (typically) |
| Non-Repeatability |
< ±0.10% of Rated Load |
| Excitation Voltage |
10vdc recommended, 15vdc maximum |
| Bridge Resistance |
350Ω |
| Insulation Resistance |
> 500MΩ @ 500vdc |
| Operating Temperature Range |
-20 to +70°C |
| Compensated Temperature Range |
-10 to +50°C |
| Zero Temperature Coefficient |
< ±0.010% of Rated Load/°C |
| Span Temperature Coefficient |
< ±0.010% of Rated Load/°C |
| Environmental Protection Level |
IP66 (IP67 optional) |
| Connection Type |
10 metre 4-core screened PUR cable (glanded exit) |
| Wiring Connections |
| Red +ve supply Blue -ve supply |
|
| Green +ve signal Yellow -ve signal |
|
| Options Available |
| |
Special ranges available
Special electrical connections
Integral signal conditioning
Centralising Bobbin
Subsea and Offshore versions
Lloyd’s, ABS or DNV witness testing |
|
|