| Rated Load (kg) |
1500, 2000, 3000, 5000 |
| Proof Load |
150% of Rated Load |
| Ultimate Breaking Load |
> 300% of Rated Load |
| Output |
2 mV/V at Rated Load (±0.1%) |
| Accuracy |
< ±0.02% of Rated Load |
| Non-Repeatability |
< ±0.01% of Rated Load |
| Excitation Voltage |
10vdc recommended, 15vdc maximum |
| Bridge Resistance |
350Ω |
| Insulation Resistance |
> 500MΩ @ 100vdc |
| Operating Temperature Range |
-30 to +70°C |
| Compensated Temperature Range |
-10 to +40°C |
| Zero Temperature Coefficient |
< ±0.004% of Rated Load/°C |
| Span Temperature Coefficient |
< ±0.002% of Rated Load/°C |
| Environmental Protection Level |
IP67 |
| Connection Type |
PVC screened cable 3m long, via cable gland |
| Wiring Connections |
| Green |
+ve supply |
Blue |
-ve supply |
| Red |
+ve signal |
White |
-ve signal |
|
| Options Available |
Can be supplied with instrumentation
Spherical seating rod end bearings
Compression load button |