ADP15-DI Dual Current and Voltage Input Digital Indicator and Controller

 ADP15 AC/DC Voltage/Current Input Digital Indicator/Controller 

  • Features
  • Specification
  • Dimensions
  • Downloads
  • Suggested Instrumentation
  • Options
  • Applications
  • Dual DC Voltage 0V to 10V or Dual DC Current 4mA to 20mA
  • Microprocessor based design
  • Peak hold
  • Independent scaling of each input
  • Full calibration & programming via keypad & communications port
  • Isolated wide range AC & DC powering
  • Isolated analogue outputs
  • Input signal relationships include:- (A+B) (A/B) (A-B) (AxB) and A = process, B + set point value with scaling factor
  • 4½ digit high resolution

The ADP15-DI range of products is very versatile, accepting a wide range of different signal input types and ranges.

The ADP15-DI flexibility makes it the first choice for many control system designers. Supporting products like PC software, printers, and sensors, means most customers can deal with a single supplier.

Outputs include:- Analogue voltage and current, industry standard digital communications, Relays, Printer Drive
Options and Accessories include:
Panel mounting via DIN rail mounting
IF25 Interface module (connects up to 25 ADPs to 1 RS232 port)
Power supplies for 110/230 V AC or 9-32V DC
Communications for Printer, PLC or PC
The ADP15-DI can be supplied with a wide range of different sensors from the LCM Systems range and can be combined with other instrumentation. Please consult the LCM technical department to discuss your application.

Input Type

Input Ranges

Order Code

DC Voltage Dual 0-10V DIV
DC Current Dual 4-20mA DIA

Outputs (analogue)

0 to 1V V1
0 to 5V V2
1 to 5V V3
0 to 10V V4
-10 to +10V V5
0-1mA A1
0-20mA A2
4-20mA A3
10-50mA A4
0-5mA A5
0-10mA A6
Pulse Frequency F1

Other Information

Accuracy Typical ±0.08% of output, ± 0.08%FSD
Resolution As display resolution, max 15 bits
Calibration By 15-turn pre sets for gain and offset
Inversion By keypad value
Isolation ±130V RMS or DC max to analogue input or to any other port
Ranging Fully keypad scalable over desired display range

Communications Port

Details

Order code

RS485/232 RS485 - For up to 32 instruments on 1 bus, 4 wire COM 1
  RS232 ­ printer or direct connection to 1 device, 3 wire  
20mA current loop For up to 25 instruments per interface, 4 wire S1

Other Information

Baud rates 300, 600, 1200, 2400, 4800, 9600 (19200 MANTRABUS only)
Electrical isolation ±130V RMS or DC max to analogue input or any other port
Formats MODBUS RTU, MANTRABUS and printer output formats

Alarm/Control Outputs

Details

Order code

SPCO 1 relay on SP1 R1
DPCO 1 relay on SP1 R2
SPCO 2 relays on SP1& 2 R3
SPCO 1 relay on SP2 R4
DPCO 1 relay on SP2 R5

Other Information

Relays 230V at 5A AC resistive
Isolation ±130V RMS
Keypad Programmable Hysteresis, Latching, Output Inversion, Delay Times
PID values and options Time Proportioning.

Power Supplies

Details

Order code

240 220V-230V AC 50-60Hz 10W 240
110 110V-120V AC 50-60Hz 10W 110
12 &24V 9-32V DC 10W isolated 12/24

Mounting Type

Order code

Front Panel P
Din Rail Adaptor D

Communication Port CP Operation

All ADP15 display data can be accessed via the communications port along with relay, PID power and EEPROM status.
All ADP15 user configurable data can be changed including EEPROM enable/disable and relay reset (ADP15 address code cannot be changed).

Other Options & Accessories

One pass calibration
20mA PC Communications Interface (IF25)
VisualLink PC SCADA Software

Base ADP15

Input Filter Programmable to average up to 64 display updates.
Displays 7 segment LED 4.5 digit 10mm.3 x 3mm LED's 2 for relay status, 1 for program and hold indication.
Update Rate Up to 10 updates per seconds

Controls

4 membrane panel keys Scroll key to view/update parameter.
  Digit select key.
  Digit increment key.
  Reset key.
  Keypad disable by internal links behind front panel.
  Hold function by digit select key when in input mode.

Data Retention/Protection

Retention 10 years for set up values, minimum of 100,000 write cycle
  Protection of data and function(s) Watchdog timer giving repeat auto resets.
  Impending power detection and hold off.
  Keypad security and time out.

CE & Environmental

Storage temperature -20 to +70ºC
Operating temperature -10 to 50°C
Relative humidity 95% maximum non condensing
Safety/Low Voltage Directive 73/23/EEC amended by 93/68/EEC xxxBS EN 61010-1
EMC Directive 89/336/EECxxx Basic Standard BS EN 61326
EMC Emissions BS EN 55011
EMC Immunity BS EN 61000-42

Physical

Case Dimensions DIN 72 x 72 x 163mm (excluding mounting terminal)
Case Material Grey Noryl, flame retardant
Weight 750 grams
Terminals 2.5mm, saddle field terminals
Accessibility All electronics removable through front panel leaving field wiring and case in situ
adp15 drawing
There are currently no options available to view from this page. To view the various input and output options available for the ADP15-DI, please view the ADP15-DI product datasheet by clicking here.
  • Load Cell  based Balancing systems
  • Differential pressure measurement
  • Pressure compensated force measurement

 

Powered By Intergage | Content Management System